Day-Brite Lighting Photometric Data IES File 25196.IES, printed on 8/8/2008 IESNA:LM-63-2002 [TEST] 25196 [TESTDATE] 03/10/2005 [LUMCAT] AVSC2CF18PMW-120-1/2-EB [LUMINAIRE] ARIOSO CLOUD SCONCE [LAMP] CFQ18W [BALLAST] TRIAD C218UNVSE [MANUFAC] DayBrite-Capri-Omega(Genlyte Group) [TESTLAB] Daybrite Lighting (Genlyte Group) Photometric Laboratory, Tupelo, MS [MORE] [200016- 0] (NVLAP) [ISSUEDATE] 3/14/2005 [_TEST_LEVEL] Expermental [_TIFF_FILE_NAME] [_VERSION] fo2ies 3.0c(0-180) Test distance = 30 ft. Shielding angle: normal 90, Parallel 90 2 lamps, 1250 Lumens/lp, Total fixt. lumens = 1601, Fixt. Eff. = 64.0% Ballast Factor 0.980, Input Watts = 35 LER = (Fixt-Eff * Lp-Lumens * BF) / Watts = 44.8 -------------------------CANDELA---------------------------- Zone -Parallel(0)- Nrm(90) ----Zonal Lumens----- Front Back Front Back Total 0 59 59 59 5 23 97 66 2 4 6 15 23 200 64 4 21 24 25 26 234 62 5 42 47 35 34 263 57 8 62 71 45 42 304 51 11 82 94 55 49 344 43 14 101 115 65 56 349 37 17 113 130 75 60 384 32 18 125 143 85 61 419 26 18 141 160 95 58 413 28 18 144 162 105 52 391 47 18 133 150 115 44 350 67 17 118 135 125 35 322 90 15 105 121 135 25 284 114 14 86 100 145 14 214 128 13 61 74 155 4 183 120 8 37 45 165 1 157 80 4 16 21 175 33 134 44 1 4 5 180 47 47 47 Spacing Criteria: 0 plane = 0.1, 180 plane = 4.1, 90 plane = 1.5 These photometric results were obtained in the Day-Brite Lighting (Genlyte/ Thomas Group) Laboratory, which is NVLAP-accredited by the National Institute of Standards and Technology. This does not constitute an endorsement of this product by NIST, NVLAP or the US Government. APPROVED BY DATE / / ******************************************************************************* Page 1 of 5 TESTED IN ACCORDANCE WITH IES PROCEDURE
IES File 25196.IES, printed on 8/8/2008
-----------------------------Zonal Lumen Summary------------------------------
Zone --------Lumens--------- -------%Lamp-------- ------%Fixture------
Front Back Total Front Back Total Front Back Total
(0-30) 11 67 78 0.4 2.7 3.1 0.7 4.2 4.8
(0-40) 19 129 148 0.8 5.2 5.9 1.2 8.1 9.3
(0-60) 44 313 357 1.8 12.5 14.3 2.8 19.5 22.3
(0-90) 97 692 789 3.9 27.7 31.6 6.1 43.2 49.3
(90-120) 52 395 447 2.1 15.8 17.9 3.3 24.7 27.9
(90-130) 67 500 567 2.7 20.0 22.7 4.2 31.2 35.4
(90-150) 95 646 741 3.8 25.9 29.7 5.9 40.4 46.3
(90-180) 109 704 812 4.3 28.1 32.5 6.8 43.9 50.7
(0-180) 206 1395 1601 8.2 55.8 64.0 12.9 87.1 100.0
-------Average Luminance(Cd/sq. meter)--------
Zone -----Parallel(0)--- Nrml(90)
Front Back
45 4603 66638 1016
50 5061 78129 877
55 5453 92961 760
60 6014 107570 660
65 6532 128000 605
70 7135 164055 541
75 7593 229968 500
80 8162 364185 449
85 8728 745162 401
ZONAL CAVITY COEFFICIENTS OF UTILIZATION
Effective floor cavity reflectance = 0.20
Ceil 80 70 50 30 10
Wall 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10
RCR
0 69 69 69 69 63 63 63 63 53 53 53 44 44 44 36 36 36
1 59 55 52 48 54 51 47 44 42 39 37 34 32 30 26 25 24
2 53 47 41 37 48 43 38 34 35 32 28 28 25 23 22 20 18
3 48 40 34 30 43 37 31 27 30 26 23 24 21 18 18 16 14
4 43 35 29 24 39 32 26 22 26 22 19 21 17 15 16 13 11
5 39 31 25 20 36 28 23 19 23 19 15 18 15 12 14 11 9
6 36 27 21 17 33 25 20 16 20 16 13 16 13 10 12 10 8
7 33 24 19 15 30 22 17 14 18 14 11 15 11 9 11 9 7
8 31 22 16 13 28 20 15 12 17 13 10 13 10 8 10 8 6
9 28 20 15 11 26 18 14 10 15 11 9 12 9 7 9 7 5
10 27 18 13 10 24 17 12 9 14 10 8 11 8 6 9 6 5
Page 2 of 5
IES File 25196.IES, printed on 8/8/2008 ---------------------CANDLEPOWER DATA------------------------------------------- Planes 0.0 22.5 45.0 67.5 90.0 112.5 135.0 157.5 180.0 Zone 0.0 59 59 59 59 59 59 59 59 59 5.0 23 27 32 46 66 74 85 93 97 10.0 20 18 17 35 66 89 116 142 148 15.0 23 19 15 25 64 107 152 189 200 20.0 25 20 15 13 63 126 180 212 220 25.0 26 22 16 11 62 143 194 226 234 30.0 29 25 17 12 60 154 201 236 247 35.0 34 27 19 12 57 163 205 249 263 40.0 37 31 20 12 54 165 208 263 283 45.0 42 35 22 13 51 163 213 277 304 50.0 46 38 24 13 47 159 222 292 324 55.0 49 41 25 13 43 154 233 309 344 60.0 53 44 26 13 39 150 244 314 347 65.0 56 47 27 13 37 148 253 314 349 70.0 59 49 28 13 34 146 257 317 362 75.0 60 49 29 13 32 144 257 325 384 80.0 61 50 29 13 29 142 275 350 408 85.0 61 50 29 13 26 149 297 372 419 90.0 60 49 29 13 23 157 308 375 416 95.0 58 48 28 13 28 157 309 373 413 100.0 56 46 27 13 36 150 301 365 404 105.0 52 43 26 14 47 151 284 350 391 110.0 49 40 25 16 57 158 269 328 372 115.0 44 37 23 18 67 163 268 308 350 120.0 39 34 21 21 78 168 272 296 333 125.0 35 30 19 25 90 172 271 290 322 130.0 30 26 16 32 102 177 265 282 310 135.0 25 21 14 44 114 182 253 255 284 140.0 20 17 13 55 122 185 238 216 239 145.0 14 13 14 72 128 185 225 192 214 150.0 9 10 16 66 132 179 207 172 196 155.0 4 9 21 49 120 165 173 149 183 160.0 1 5 27 54 99 131 134 127 169 165.0 1 0 24 59 80 104 111 120 157 170.0 13 4 3 41 63 66 95 116 148 175.0 33 30 8 12 44 28 65 110 134 180.0 47 47 47 47 47 47 47 47 47 Page 3 of 5
IES File 25196.IES, printed on 8/8/2008
Photometric Data in IES format
IESNA:LM-63-2002
[TEST] 25196
[TESTDATE] 03/10/2005
[LUMCAT] AVSC2CF18PMW-120-1/2-EB
[LUMINAIRE] ARIOSO CLOUD SCONCE
[LAMP] CFQ18W
[BALLAST] TRIAD C218UNVSE
[MANUFAC] DayBrite-Capri-Omega(Genlyte Group)
[TESTLAB] Daybrite Lighting (Genlyte Group) Photometric Laboratory, Tupelo, MS
[MORE] [200016- 0] (NVLAP)
[ISSUEDATE] 3/14/2005
[_TEST_LEVEL] Expermental
[_TIFF_FILE_NAME]
[_VERSION] fo2ies 3.0c(0-180)
Test distance = 30 ft.
Shielding angle: normal 90, Parallel 90
TILT=NONE
2 1250 1 37 9 1 1 0.0833333 0.833333 0.833333
0.98 1 35
0 5 10 15 20 25 30 35 40 45
50 55 60 65 70 75 80 85 90 95
100 105 110 115 120 125 130 135 140 145
150 155 160 165 170 175 180
0 22.5 45 67.5 90 112.5 135 157.5 180
59 23 20 23 25 26 29 34 37 42
46 49 53 56 59 60 61 61 60 58
56 52 49 44 39 35 30 25 20 14
9 4 1 1 13 33 47
59 27 18 19 20 22 25 27 31 35
38 41 44 47 49 49 50 50 49 48
46 43 40 37 34 30 26 21 17 13
10 9 5 0 4 30 47
59 32 17 15 15 16 17 19 20 22
24 25 26 27 28 29 29 29 29 28
27 26 25 23 21 19 16 14 13 14
16 21 27 24 3 8 47
59 46 35 25 13 11 12 12 12 13
13 13 13 13 13 13 13 13 13 13
13 14 16 18 21 25 32 44 55 72
66 49 54 59 41 12 47
59 66 66 64 63 62 60 57 54 51
47 43 39 37 34 32 29 26 23 28
36 47 57 67 78 90 102 114 122 128
132 120 99 80 63 44 47
59 74 89 107 126 143 154 163 165 163
159 154 150 148 146 144 142 149 157 157
150 151 158 163 168 172 177 182 185 185
179 165 131 104 66 28 47
59 85 116 152 180 194 201 205 208 213
222 233 244 253 257 257 275 297 308 309
301 284 269 268 272 271 265 253 238 225
207 173 134 111 95 65 47
59 93 142 189 212 226 236 249 263 277
292 309 314 314 317 325 350 372 375 373
Page 4 of 5
IES File 25196.IES, printed on 8/8/2008
365 350 328 308 296 290 282 255 216 192
172 149 127 120 116 110 47
59 97 148 200 220 234 247 263 283 304
324 344 347 349 362 384 408 419 416 413
404 391 372 350 333 322 310 284 239 214
196 183 169 157 148 134 47