| TYPICAL LIGHT LOSS FACTORS(1) |
|
Close this Window |
| LAMP |
BALLAST TYPE |
TOTAL LIGHT LOSS FACTOR (LLF) |
| |
|
|
| 13W PLC COMPACT FLUORESCENT |
ELECTRONIC |
0.77 |
| 18W PLC COMPACT FLUORESCENT |
ELECTRONIC |
0.77 |
| 26W PLC COMPACT FLUORESCENT |
ELECTRONIC |
0.77 |
| |
|
|
| 18W PLT COMPACT FLUORESCENT |
ELECTRONIC |
0.77 |
| 26W PLT COMPACT FLUORESCENT |
ELECTRONIC |
0.77 |
| 32W PLT COMPACT FLUORESCENT |
ELECTRONIC |
0.75 |
| 42W PLT COMPACT FLUORESCENT |
ELECTRONIC |
0.75 |
| |
|
|
| 40W PLL COMPACT FLUORESCENT |
ELECTRONIC |
0.81 |
| 50W PLL COMPACT FLUORESCENT |
ELECTRONIC |
0.89 |
| 55W PLL COMPACT FLUORESCENT |
ELECTRONIC |
0.76 |
| 80W PLL COMPACT FLUORESCENT |
ELECTRONIC |
0.80 |
| |
|
|
| 14W T5 FLUORESCENT |
ELECTRONIC |
0.90 |
| 24W T5HO FLUORESCENT |
ELECTRONIC |
0.86 |
| 28W T5 FLUORESCENT |
ELECTRONIC (EB95) |
0.81 |
| 28W T5 FLUORESCENT |
ELECTRONIC (EB115) |
0.98 |
| 28W T5 FLUORESCENT |
ELECTRONIC (EB) |
0.86 |
| 54W T5HO FLUORESCENT |
ELECTRONIC |
0.86 |
| 80W T5HO FLUORESCENT |
ELECTRONIC |
0.86 |
| |
|
|
| 17W T8 LINEAR FLUORESCENT |
ELECTRONIC |
0.74 |
| 17W T8 LINEAR FLUORESCENT |
ELECTRONIC-HIGH BALLAST FACTOR |
1.08 |
| 25W T8 LINEAR FLUORESCENT |
ELECTRONIC |
0.73 |
| 32W T8 LINEAR FLUORESCENT |
ELECTRONIC-STANDARD |
0.75 |
| 32W T8 LINEAR FLUORESCENT |
ELECTRONIC-LOW BALLAST FACTOR |
0.66 |
| 32W T8 LINEAR FLUORESCENT |
ELECTRONIC-HIGH BALLAST FACTOR |
1.02 |
| 32W T8 U-BENT FLUORESCENT |
ELECTRONIC |
0.72 |
| 59W T8 8' SLIMLINE FLUORESCENT |
ELECTRONIC |
0.70 |
| 86W T8 8' HO FLUORESCENT |
ELECTRONIC |
0.71 |
| |
|
|
| 40W T12 LINEAR FLUORESCENT |
MAGNETIC |
0.77 |
| 75W T12 SLIMLINE FLUORESCENT |
MAGNETIC |
0.88 |
| 110W T12 8' HO FLUORESCENT |
MAGNETIC |
0.77 |
| |
|
|
| 175W STANDARD METAL HALIDE |
CWA |
0.59 |
| 250W STANDARD METAL HALIDE |
CWA |
0.59 |
| 400W STANDARD METAL HALIDE |
CWA |
0.59 |
| 1000W STANDARD METAL HALIDE |
CWA |
0.58 |
| |
|
|
| 175W PULSE START METAL HALIDE |
CWA |
0.72 |
| 200W PULSE START METAL HALIDE |
CWA |
0.72 |
| 250W PULSE START METAL HALIDE |
CWA |
0.72 |
| 320W PULSE START METAL HALIDE |
CWA |
0.72 |
| 350W PULSE START METAL HALIDE |
CWA |
0.72 |
| 400W PULSE START METAL HALIDE |
CWA |
0.72 |
| 450W PULSE START METAL HALIDE |
CWA |
0.72 |
| 875W PULSE START METAL HALIDE |
CWA |
0.72 |
| 1000W PULSE START METAL HALIDE |
CWA |
0.72 |
| |
|
|
| 100W HPS |
ALL |
0.81 |
| 150W HPS |
ALL |
0.81 |
| 200W HPS |
ALL |
0.81 |
| 310W HPS |
ALL |
0.81 |
| 400W HPS |
ALL |
0.81 |
| 1000W HPS |
ALL |
0.81 |
| |
|
|
| (1) THE TYPICAL LIGHT LOSS FACTORS SHOWN HEREIN ARE INTENDED TO SERVE AS A GENERAL GUIDE TO ASSIST YOU IN YOUR DESIGN. |
|
|
| LAMPS AND BALLASTS FROM VARIOUS MANUFACTURERS, ALONG WITH ENVIRONMENTAL CONDITIONS AT DIFFERENT JOB SITES, MAY |
|
|
| RESULT IN VARIATIONS FROM THE LIGHT LOSS FACTORS PROVIDED ABOVE. |
|
|